RULE Livewell Motor Cartridge suits 500-800-1100 GPH
- These are spare or replacement motor cartridge suitable to the following pumps: (Pumps are sold seperately)
- 500 GPH RWB5232, RWB5230, RWB5231
- 800 GPH RWB5235, RWB5233, RWB5236
- 1100 GPH RWB5238, RWB5236, RWB5237
See the complete specifications in the table below.
| PRODUCT PART NUMBER | RULE MODEL NUMBER | SUITS | VOLTAGE | REQUIRED FUSE SIZE | GPH @ OPEN FLOW (LPH) | GPH @ 3.3 ft. (LPH @ 1m) |
| SP0910 | 65DR | 500GPH – RWB5230, 5231 and 5232 Pumps | 12V DC | 5A | 500 GPH (1892 LPH) | 425 GPH (1609 LPH) |
| SP0911 | 66DR | 800GPH – RWB5233, 5234 and 5235 Pumps | 12V DC | 7.5A | 800 GPH (3028 LPH) | 600 GPH (2271 LPH) |
| SP0912 | 67DR | 1100GPH – RWB5236, 5237 and 5238 Pumps | 12V DC | 7.5A | 1100 GPH (4163 LPH) | 825 GPH (3123 LPH) |
Refer to Xylem website for further details on user guide.
TO CHANGE MOTOR CARTRIDGE (Refer to image gallery for visual guide)
- 1. Block off the thru-hull before removing the motor cartridge.
- 2. Disconnect wiring.
- 3. Press cartridge release button, twist counterclockwise and pull motor cartridge straight up.
- 4. Reconnect wire to new motor cartridge.
- 5. Install the new motor cartridge and press down firmly. Twist motor housing clockwise until cartridge locks in place. A “click” should be heard when the cartridge is locked.
- 6. Open or unblock thru-hull to begin use.
WARNING: The operator of the vessel should ensure the motor cartridge is in the fully locked position at all times when the vessel is in the water. Failure to place the motor cartridge in the fully locked position could result in water intrusion, flooding, property damage, severe personal injury and/or death.