Hansen 63mm (2 1/2”) Foot Valve BSPT / HFV63
This is used on the end of a suction line to stop fluids in the line emptying when the pump is turned off, thus eliminating the need to prime your pump at start up.
SPECIFICATIONS
- PRODUCT CODE: HFV63
- CODE MEANING: HANSEN FOOT VALVE
- THREAD TYPE: BSPT
- FOOT VALVE TECHNICAL SPECIFICATIONS (See visual flow chart in image gallery)
- MAXIMUM PRESSURE @ 20ºC/68ºF: 16 Bar (1600 kPa, 235psi)
- CHEMICAL RESISTANCE OF FOOT AND CHECK VALVE
- Please refer to the attached images for full chart of chemical resistance.
- VACUUM REQUIRED FOR INITIAL FLOW: -0.5psi, -3.5kPa
- VACUUM REQUIRED TO FULLY OPEN DIAPHRAM: -1.5psi, -10.0kPa
- MINIMUM FLOW FOR SELF CLEANING ACTION: 600 l/min
- DIMENSIONS (Refer to the attached images for visual dimensions chart)
- METRIC: 63mm
- IMPERIAL: 2 1/2”
- DIMENSIONS
- DIAMETER (Size A): 152mm
- LENGTH (Size B): N/A
- Size C: 156mm
- T1 BSPT (THREAD SIZE): 2 1/2″ (63mm)
- INSTALLATION: Valve will operate at any angle
- MAXIMUM OPERATING TEMPERATURE: 60ºC
- FOOT VALVE PARTS AND MATERIALS
- Strong, Non-corrosive Materials
- BODY: High Quality Glass Fibre Reinforced Nylon
- DIAPHRAGM: Nitrile Rubber
- SPRING: Stainless Steel
- All components of this valve are
manufactured from materials approved for use with potable (drinkable) water.
- Foot Valves are AWQC AS/NZS 4020:2018 Approved Product, refer to Hansen Australia Website.
- SPARE OR REPLACEMENT PARTS: HVD63, 63mm (2 1/2″) FV & CV Diaphragm & Spring
FEATURES AND BENEFITS
- High performance, cost effective Foot Valve, delivers high volumes of water quickly with unrestricted full flow.
- Efficiency in excess of 95% compared to many other types of valves.
- Operates via pressure differential and at any angle or position.
- No poppet valve to wear or jam.
- Easy access screw cap for servicing, diaphragm and spring are interchangeable with the same size Check Valve.
- Blockages are reduced due to low fluid velocity through slots.
- All connecting threads are BSPT.
- Smooth operating valve for high efficiency.
- Unique design which incorporates a self-cleaning diaphragm.
- Manufactured from strong, non-corrosive, UV stabilised materials.
- Materials approved for use with potable (drinkable) water.
OTHER AVAILABLE FOOT VALVE DIMENSIONS (Available as seperate purchase)
- HFV25 1″ (25mm)
- HFV32 1 1/4″ (32mm)
- HFV40 1 1/2″ (40mm)
- HFV50 2″ (50mm)
ABOUT HANSEN FOOT VALVES
- Hansen Foot Valves are used on the end of a suction line to stop fluids in the line emptying when the pump is turned off, thus eliminating the need to prime your pump at start up. The unique design gives you more flow in less time, which saves on pumping costs. It has unrestricted Full
Flow and has an efficiency in excess of 95% of many other types of Foot Valves. The unique product design incorporates a built in strainer and operates at any angle or position.
FOOT VALVE INSTALLATION
- Use a thread sealant on all threaded connections. It is recommended to use Loctite 5331.
- Screw fitting into the foot valve. Do not over tighten. Hand tight plus maximum of two turns with tools.
- All pipe work must be adequately supported.
- This can be installed at any angle.
FOOT VALVE RE-ASSEMBLY INSTRUCTIONS
- These instructions are for those situations where you need to clean out the valve in the event that grit or debris has reduced its working efficiency.
- Turn Foot Valve body upside down (as per picture).
- Seat the diaphragm into the valve body.
- If spring is removed, place it over the pin and turn.
anti-clockwise whilst pushing firmly to retain it on the spigot. - Place the cap onto the valve body.
- Screw the cap fully onto the valve body and tighten down, hand tight only. For the 63mm valve, use the lugs to tighten the cap a further 1/4 to 1/3 turn until it stops.
NOTE: Before re-assembling make sure that all components are fully cleaned.
The information given on this sheet is for guidance only. HANSEN PRODUCTS (NZ) LIMITED accepts no responsibility for the misuse or misapplication of this information.
HANSEN FOOT VALVES BROCHURE AND CHEAT SHEETS
- For HANSEN Foot Valves Brochure and Cheat Sheet Guide, refer to Hansen Australia Website.
HANSEN FOOT VALVES VIDEO GUIDES & COMMERCIALS
- For HANSEN Foot Valves Handy Tips and Commercial Videos, refer to Hansen Australia Website.
FREQUENTLY ASKED QUESTIONS
- QUESTION: I have an existing water line with a 40mm valve on it and I want to replace the valve with a Hansen Valve. Do I use the same size valve as my existing one?
- ANSWER: You will need to refer to the Choosing the Correct Foot or Check Valve Page under the Technical Info / Pressure & Flow Rates Tab of each valve product and use these charts to determine the valve size required. In some situations you may be able to use a smaller Hansen valve than your existing non Hansen valve.
- QUESTION: Can I use my Hansen fittings with my swimming pool/spa pool set up?
- ANSWER: No, as the high concentration of chlorine used in the water for pools will attack the material. The fitting material is only suitable for use with domestic water. Hansen products that are used in this application will not be covered by our Hansen Warranty.
- QUESTION: Can the Hansen Foot Valves be used with salt water passing through them?
- ANSWER: The spring in the valves is made of 302 grade stainless steel, and may eventually corrode in the salt water. The spring is available as a replacement part if required. All other parts of the valve are fully resistant to salt water.
- QUESTION: Do I have to remove my valve from the line to service?
- ANSWER: No. Your valve can be left inline for servicing. Refer to Re-assembly instructions for further information.
- QUESTION: How do I know what size valve to use?
- ANSWER: Work out the flow of your pump (your pump installer/supplier can help you here) then refer to Choosing the correct Foot or Check Valve under the Technical Info / Pressure & Flow Rates Tab of each product.
- QUESTION: I find my check valves too often not sealing, I’ve been told I should have a filter upstream of the valve, is this the same with the Hansen Check Valve?
- ANSWER: All check valves should be screened upstream. The advantage of the Hansen Check Valve is that they can be serviced in line if your water is dirty.
- QUESTION: I have noticed that the Hansen Check Valve has a screw top, does that mean it can be serviced inline?
- ANSWER: Yes, the Hansen Check Valve can be serviced inline and any parts replaced if required.
- QUESTION: The dam I’m pumping from can get quite dirty at times, including some slime and weed. I find my existing foot valve requires constant cleaning. Will the Hansen Foot Valve solve this problem?
- ANSWER: Yes the Hansen Foot Valve has been designed with the ability to work in dirty water situations and because of lower head losses of this valve you can select a smaller size than you normally would expect, thus with the higher velocities across the diaphragm the valve becomes self-cleaning.
- QUESTION: The river I pump from is fairly shallow so I do pump some sand at times and find my existing Foot Valves have to be replaced often. Is the Hansen Foot Valve also a throw away valve?
- ANSWER: No, although pumping sand is unadvisable because of the damage to your pump. You will find with the screw cap service access to the Hansen Foot Valve you only need to replace the parts that wear in these circumstances. Another suggestion would be because the Hansen Foot Valve can be installed at any angle you may be able to install the Hansen Foot Valve vertically above your suction pipe and keep it above the sand.
- QUESTION: What temperature can I use Hansen Foot or Check Valve at?
- ANSWER: Hansen have tested all its products for use with cold water up to a maximum temperature of 60°C (140°F). We do not recommend the use of these products with temperatures higher than 60°C (140°F) as plastic expands due to temperature increases. Hansen cannot guarantee the products will perform when used with temperatures over 60°C (140°F). Hansen products that have failed in temperatures higher than 60°C (140°F) will not be covered by our Hansen Warranty.
- QUESTION: When choosing my Foot Valve do I select a valve size to match the suction pipe diameter?
- ANSWER: No, not necessarily, again because of the higher flow efficiencies of the Hansen Foot Valve you match your flow with the head loss your pump can afford, generally you will find the Hansen Foot Valve size will be less than the pipe diameter. To choose the correct sized valve for your application, refer to the Choosing the Correct Foot or Check Valve Page under the Technical Info / Pressure & Flow Rates Tab of each product.
- QUESTION: Why won’t my valve seal?
- ANSWER: 1. There may be something sitting between the diaphragm and diaphragm seating area. Pull the valve apart and clean out (replace diaphragm if damaged) as per assembly instructions.
2. Check to ensure that you are using the correct size valve for your situation (see choosing the correct foot valve or check valve).